Name |
Federal Standard, Specification |
Application |
Technical characteristics |
Constructive micaceous laminate IZKAH |
Spec. 3492 - 027 - 00281944-01 |
as rigid electric insulating strips and frames of heating
spirals for heaters |
Sheet size:
800x800
Thickness:
0,4-1,2 mm |
Thermal resistance: up to 800 C
Electrical strength: not less than 16 kW/mm |
Flexible micaceous laminate IFG-KAHF |
Spec. 3492 - 086 - 00281915 - 02 |
as flexible electric insulating materials for heaters
(heating spirals and others) |
Sheet size:
850x560
Thickness:
0,2; 0,3; 0,5 mm |
Thermal resistance: up to 900 C
Electrical strength: not less than 15 kW/mm |
Capacitor micaceous laminate KIFSH, KIFP, KIFE, KIFK |
Spec. 3492 – 026 - 00281944 |
as electric insulating strips between commutator segments
for electric machines |
Sheet size:
800x800
Thickness: 0,4-1,2 mm |
Operating temperature: up to 155 C. Electrical strength:
not less than 22 kW/mm |
Separating micaceous laminate ITPFA, ITPFD |
Spec. 3492 - 009 - 00284397 - 98 |
as rigid strips and frames of electric heating elements
for heaters |
Sheet size:
550x300
Thickness: 0,5-2,0 mm |
Thermal resistance: more than 700 C. Average electrical
strength: 18 kW/mm |
Separating micaceous laminate PIFT |
Spec. 21 - 25 - 327 - 90 |
as electric insulating strips for electric
machines |
Sheet size:
200x900
Thickness: 0,3-2,0 mm |
Thermal resistance: up to 155 C. Average electrical strength:
26 kW/mm |
Separating micaceous laminate PIFE, PIFE-SH |
Spec. 16 - 90 - 479.0184.002 |
Sheet size:
200x900
Thickness: 0,25-5,0 mm |
Thermal resistance: up to 155 C. Average electrical strength:
26 kW/mm |
Separating micaceous laminate PIFK |
Spec. 16 - 90 - 479.0184.001 |
Sheet size:
200x900
Thickness: 0,15-2,0 mm |
Thermal resistance: up to 180 C. Average electrical strength:
26 kW/mm |
Wet-strength micaceous laminate GIK-S-PL (v); GIK-S-SPL
(v) |
Spec. 3492 - 001 - 00281884 - 00 |
Flexible insulation |
Sheet size:
850x670
Thickness: 0,25-0,55 mm |
Operating temperature: up to 155 C. Average disruption
voltage: 9 kW/mm |
Molding micaceous laminate FIP-APL |
16 - 503.121 - 79 |
as an electric insulating material formed when heated |
Sheet size:
840x540
Thickness: 0,25; 0,30; 0,35 mm |
Operating temperature: up to 155 C. Average electrical
strength: 40 kW/mm |
Molding micaceous laminate FIP-T |
21 - 0281916 - 31 - 91 |
as electric insulating material formed when heated |
Sheet size:
850x550
Thickness: 0,25; 0,30 mm |
Average electrical strength: 30 kW/mm. Operating temperature:
up to 155 C |
Molding micaceous laminate FIP-AHF-APL |
3492 - 057 - 00281915 - 98 |
electric insulating material, used inside insulating constructions
of traction machines |
Sheet size:
850x560
Thickness: 0,25; 0,30 mm |
Operating temperature: up to 155 C. Average electrical
strength: 38 kW/mm. |
Molding micaceous laminate FIFK-T |
21 - 00291915 - 35 - 94 |
for capacitor cuffs and formed insulating components of
electric machines |
Sheet size:
850x650
Thickness: 0,25; 0,30 mm |
Operating temperature: up to 180 C. Average electrical
strength: 30 kW/mm |